Promark
WhatsApp
All products
Vutlan VT560 Smoke Detector

Vutlan VT560 — Smoke Detector

Photoelectric smoke detector connecting to the analog port of Vutlan master units. Ceiling-mounted; up to 10 detectors in a chain are monitored as one element. Delivers early smoke warnings from server rooms, cabinets and technical spaces via SNMP, e-mail or SMS.

Duman DedektörüSmokeAnalogDaisy ChainFire Safety
Vutlan VT560 — Smoke Detector

Specifications

Tip / Type
Analog fotoelektrik duman dedektörü
Üretici / Manufacturer
Vutlan s.r.o. (Bratislava, Slovakya)
Zincir / Daisy chain
Evet — 10 adede kadar, tek eleman
Bağlantı / Connection
2 × RJ12
Maks. mesafe / Max distance
150 m (ana üniteden / VT408'den)
Maks. montaj yüksekliği / Max height
6 m (tavan)
Güç tüketimi / Power consumption
100 mW
Çalışma / Operating
Optimal −10…+55 °C, genişletilmiş −10…+80 °C; %5–95 RH
Ömür / Lifespan
≥10 yıl
Boyutlar / Dimensions
Ø100 × 45 mm, 150 g
Uyumlu ana üniteler / Compatible
VT225t, VT335G, VT336t, VT825G, VT855G, VT604G, VT608G ve VT408 analog portları
GTIN
8588009886198
Garanti / Warranty
90 gün (Vutlan uzantı/aksesuar garantisi); AB üretimi

Key features

  • Photoelectric smoke detection; red status LED.
  • Analog sensor — 2 × RJ12 ports; up to 10 detectors per chain, the chain appears as one element.
  • Max 150 m from the master unit or VT408; max installation height 6 m, ceiling mount.
  • Operating: optimal −10…+55 °C (extended −10…+80 °C), 5–95% RH; 100 mW.
  • Average lifespan ≥10 years; Ø100 × 45 mm, 150 g.
  • Package: detector, 2 m RJ11 6P4C cable, sensor bracket and mounting hardware.
  • Compatible: VT225t, VT335G, VT336t, VT825G, VT855G, VT604G, VT608G and VT408 analog ports.
  • Note: does not replace a building fire detection system; provides early warning for environmental monitoring.
  • Promark: detector placement, chain planning and testing.

Typical applications

01

Server room and data center ceiling — early smoke warning.

02

UPS and battery rooms, electrical switchboard rooms.

03

Telecom cabinets and outdoor shelters.

04

Unattended technical spaces such as archives and storage.

Related Solutions

Related Products

Vutlan VT825G — 1U Data Center Monitoring Unit
Vutlan VT825G — 1U Data Center Monitoring Unit

19" 1U environmental monitoring and I/O control unit for mid-to-large data centers, telecom facilities and critical infrastructure. 8 analog sensor ports, CAN bus, 16 dry-contact inputs, 2 × 10A power relays and 2 × 12V outputs; scales to 130 physical sensors and 1000 elements. Gigabit LAN, dual AC/DC power options, VT7670 LTE modem and backup battery slot.

Details
Vutlan VT335G — Compact Environmental Monitoring Unit
Vutlan VT335G — Compact Environmental Monitoring Unit

Compact metal-housed monitoring unit for server rooms, cabinets and small-to-mid data rooms. 4 analog sensor ports, CAN bus, 4 dry-contact inputs, 2 × 12V outputs and Gigabit LAN; VT7670 LTE modem and Modbus RTU / OSDP slot. Desktop unit; mounts in 19" 1U, on DIN rail or wall with accessories. Current successor of the end-of-sale VT335i.

Details
Vutlan VT408 — 8-Port Analog Sensor Extension Unit
Vutlan VT408 — 8-Port Analog Sensor Extension Unit

Extension unit that adds +8 analog sensor ports to Vutlan master units over CAN bus. Sensors are auto-detected; up to 24 VT408 units can be chained on one CAN line, with bus length up to 225 m. Used when the master unit runs out of ports or sensors are clustered in a remote rack.

Details
Vutlan VT109 — 3-Tier Light Tower Alarm Beacon (Red/Yellow/Green)
Vutlan VT109 — 3-Tier Light Tower Alarm Beacon (Red/Yellow/Green)

3-tier LED light tower providing visual alarm notification for monitoring systems. Red (critical) / Yellow (warning) / Green (normal) three-level design. Connects directly to 12V DC, 0.25A electronic relay outputs of Vutlan monitoring units. Compatible with 3rd-party controllers. Desktop, surface or rack mounting.

Details
Vutlan VT560 — Smoke Detector

Photoelectric smoke detector connecting to the analog port of Vutlan master units. Ceiling-mounted; up to 10 detectors in a chain are monitored as one element. Delivers early smoke warnings from server rooms, cabinets and technical spaces via SNMP, e-mail or SMS.