Vutlan VT490 Humidity and Temperature Sensor (CAN)

Vutlan VT490 — CAN Humidity and Temperature Sensor

High-accuracy temperature and humidity sensor that daisy-chains over CAN bus. Connected in series on a single cable for multi-point measurement at rack fronts/backs, hot/cold aisles or around a room. Each parameter is a separate element in the web interface; dew point is calculated in the interface.

Sıcaklık SensörüNem SensörüCANDaisy ChainData Center
Vutlan VT490 — CAN Humidity and Temperature Sensor

Specifications

Tip / Type
CAN dijital sıcaklık + nem sensörü
Üretici / Manufacturer
Vutlan s.r.o. (Bratislava, Slovakya)
Sıcaklık doğruluğu / Temperature accuracy
±0.4 °C (−10…+85 °C), çözünürlük 0.1 °C
Nem doğruluğu / RH accuracy
±3% RH (0–80% RH)
Arayüz / Interface
CANopen, 2 × RJ11 6P4C, daisy chain
Maks. mesafe / Max distance
225 m (ana üniteden)
Besleme / Power
12V DC, 1 W
Çalışma / Operating
−40…+100 °C, 0–95% RH
Boyutlar / Dimensions
68 × 47 × 26 mm
Montaj / Mounting
Masaüstü, duvar
GTIN
8588009886297
Garanti / Warranty
90 gün (Vutlan ürün sayfası); AB üretimi

Key features

  • Temperature accuracy ±0.4 °C (−10…+85 °C), resolution 0.1 °C.
  • Relative humidity accuracy ±3% RH (0–80% RH).
  • CAN (CANopen) digital sensor — 2 × RJ11 6P4C ports, daisy chain.
  • Max 225 m from the master; 24 devices recommended per CAN line, an extra CAN-12V-1A supply per 12 devices.
  • Temperature and humidity are separate elements — individual thresholds and notifications; dew point calculated.
  • Operating −40…+100 °C, 0–95% RH; 12V DC, 1 W.
  • TR switch (last device on the line) and RUN/ERR LEDs; desktop or wall mounting.
  • 68 × 47 × 26 mm; compatible masters: VT225t, VT335G, VT336t, VT825G, VT855G, VT604G/VT608G, VT-PDU, LR800.
  • Promark: hot/cold aisle measurement-point plan and CAN chain design.

Typical applications

01

Rack front (cold) and rear (hot) measurement — many racks on one CAN chain.

02

Hot/cold aisle balance and cooling-efficiency tracking.

03

Server room, UPS and battery room climate monitoring.

04

Humidity-sensitive spaces such as warehouses, archives and greenhouses.

Related Solutions

Related Products

Vutlan VT825G — 1U Data Center Monitoring Unit
Vutlan VT825G — 1U Data Center Monitoring Unit

19" 1U environmental monitoring and I/O control unit for mid-to-large data centers, telecom facilities and critical infrastructure. 8 analog sensor ports, CAN bus, 16 dry-contact inputs, 2 × 10A power relays and 2 × 12V outputs; scales to 130 physical sensors and 1000 elements. Gigabit LAN, dual AC/DC power options, VT7670 LTE modem and backup battery slot.

Details
Vutlan VT335G — Compact Environmental Monitoring Unit
Vutlan VT335G — Compact Environmental Monitoring Unit

Compact metal-housed monitoring unit for server rooms, cabinets and small-to-mid data rooms. 4 analog sensor ports, CAN bus, 4 dry-contact inputs, 2 × 12V outputs and Gigabit LAN; VT7670 LTE modem and Modbus RTU / OSDP slot. Desktop unit; mounts in 19" 1U, on DIN rail or wall with accessories. Current successor of the end-of-sale VT335i.

Details
Vutlan VT855G — 1U Corporate Data Center Monitoring Unit
Vutlan VT855G — 1U Corporate Data Center Monitoring Unit

Top model of the Vutlan range: 19" 1U monitoring and I/O control unit for large data centers and multi-site enterprises. 1 GHz CPU, Gigabit LAN, 8 analog ports, 2 separate CAN ports, 32 dry-contact inputs, 8 isolated dry-contact outputs and 2 × 10A power relays; 150 physical sensors and 1000 elements. Dual AC/DC power, VT7670 LTE modem and backup battery slot.

Details
Vutlan VT408 — 8-Port Analog Sensor Extension Unit
Vutlan VT408 — 8-Port Analog Sensor Extension Unit

Extension unit that adds +8 analog sensor ports to Vutlan master units over CAN bus. Sensors are auto-detected; up to 24 VT408 units can be chained on one CAN line, with bus length up to 225 m. Used when the master unit runs out of ports or sensors are clustered in a remote rack.

Details
Vutlan VT490 — CAN Humidity and Temperature Sensor

High-accuracy temperature and humidity sensor that daisy-chains over CAN bus. Connected in series on a single cable for multi-point measurement at rack fronts/backs, hot/cold aisles or around a room. Each parameter is a separate element in the web interface; dew point is calculated in the interface.