Vutlan VT109 — 3-Tier Light Tower Alarm Beacon (Red/Yellow/Green)
3-tier light tower providing visual alarm notification for monitoring systems. Red (critical) / Yellow (warning) / Green (normal) three-level design. Connects directly to 12V DC, 0.25A electronic relay outputs of Vutlan monitoring units. Compatible with 3rd-party controllers. Desktop, surface, enclosure rack or wall mounting.

From the same family














Specifications
- Type
- Light tower alarm beacon (3-tier)
- Manufacturer
- Vutlan
- Model
- VT109
- Lights
- Red, Yellow, Green (3-tier)
- Rated voltage
- 12V DC
- Connection
- Vutlan 12V DC / 0.25A electronic relay outputs + compatible with 3rd-party controllers
- IP rating
- IP54
- Operating temperature
- -50°C to +105°C
- Operating humidity
- 5% - 95% (non-condensing)
- Mounting
- Desktop, surface, enclosure rack, wall
- GTIN
- 8588009886747
- Cable
- 2 m, RJ9 4P4C → 3P 3.81 mm
- Dimensions
- ∅50 × 310 mm (550 mm with stand), 150 g
- Warranty
- 3 months; made in the EU
Key features
- 3-tier visual alarm — Red, Yellow, Green lights.
- 12V DC supply.
- Connects directly to 12V DC / 0.25A relay outputs of Vutlan monitoring units.
- Compatible with 3rd-party controllers.
- IP54 ingress protection.
- Wide operating temperature: -50°C to +105°C.
- Operating humidity range: 5-95% (non-condensing).
- Flexible mounting: desktop, surface, enclosure rack or wall.
- Works with the 12V outputs of Vutlan VT335G / VT336t / VT825G / VT855G / VT604G (uses E1 + E2 together).
- GTIN: 8588009886747.
- Promark: monitoring system integration, alarm scenario design (critical/warning/normal mapping), cabinet placement planning.
Typical applications
Data-center alarm panel — visual alert for temperature/humidity/water-leak critical events.
Server room / network cabinet — on-site illuminated notification before remote intervention.
Industrial control room — Vutlan VT825G main + VT109 for shift-operator visibility.
Telecom CO — 3-tier alert on critical current/temperature threshold breach.
Cold storage / pharma — visual critical alarm when temperature outside safe range.
Related Solutions
Related Products

Vutlan VT825G — 1U Data Center Monitoring Unit
19" 1U environmental monitoring and I/O control unit for mid-to-large data centers, telecom facilities and critical infrastructure. 8 analog sensor ports, CAN bus, 16 dry-contact inputs, 2 × 10A power relays and 2 × 12V outputs; scales to 130 physical sensors and 1000 elements. Gigabit LAN, dual AC/DC power options, VT7670 LTE modem and backup battery slot.
Details
Vutlan VT335G — Compact Environmental Monitoring Unit
Compact metal-housed monitoring unit for server rooms, cabinets and small-to-mid data rooms. 4 analog sensor ports, CAN bus, 4 dry-contact inputs, 2 × 12V outputs and Gigabit LAN; VT7670 LTE modem and Modbus RTU / OSDP slot. Desktop unit; mounts in 19" 1U, on DIN rail or wall with accessories.
Details
Vutlan VT604G — 4-Outlet Switched PDU + Monitoring Unit
Smart PDU combining remote on/off/reboot and environmental monitoring in a single 1U rack unit. 4 × IEC C13 switched outlets, 8 analog sensor ports, 2 CAN ports, 2 dry contacts, 2 × 12V outputs; up to 700 elements of logic, triggers and notifications. VT7670 LTE modem, Modbus RTU/OSDP and backup battery slots.
Details
Vutlan VT560 — Smoke Detector
Photoelectric smoke detector connecting to the analog port of Vutlan master units. Ceiling-mounted; up to 10 detectors in a chain are monitored as one element. Delivers early smoke warnings from server rooms, cabinets and technical spaces via SNMP, e-mail or SMS.
Details3-tier light tower providing visual alarm notification for monitoring systems. Red (critical) / Yellow (warning) / Green (normal) three-level design. Connects directly to 12V DC, 0.25A electronic relay outputs of Vutlan monitoring units. Compatible with 3rd-party controllers. Desktop, surface, enclosure rack or wall mounting.