Vutlan VT408 — 8-Port Analog Sensor Extension Unit
Extension unit that adds +8 analog sensor ports to Vutlan master units over CAN bus. Sensors are auto-detected; up to 24 VT408 units can be chained on one CAN line, with bus length up to 225 m. Used when the master unit runs out of ports or sensors are clustered in a remote rack.

From the same family














Specifications
- Type
- CAN bus analog sensor expansion unit
- Manufacturer
- Vutlan s.r.o. (Bratislava, Slovakia)
- Analog port
- 8 × RJ11/RJ12 6P4C (auto-sensing)
- CAN ports
- 2 × RJ12 (daisy chain)
- Max per line
- 24 × VT408 (if no other CAN devices)
- Bus length
- max 225 m
- Analog cable
- 50–150 m (depending on sensor)
- Power
- 12V DC (adapter included)
- Compatible masters
- VT225t, VT335G, VT336t, VT825G, VT855G, VT604G, VT608G, VT-PDU 4PS/4MS, LR800
- Mounting
- Desktop, VT123 (wall), VT125t / VT122t (19" 1U), DRP-03 (DIN)
- Dimensions
- 129 × 28.6 × 56 mm
- Operating conditions
- −10…+80 °C
- Warranty
- 90 days (Vutlan extension/accessory warranty); made in the EU
Key features
- 8 × RJ11/RJ12 6P4C analog sensor ports (A1–A8) — sensor type auto-detected.
- 2 × RJ12 CAN ports — daisy-chain connection to the master unit and other CAN devices.
- Up to 24 VT408 units on one CAN line (if no other CAN devices are present); max CAN bus length 225 m.
- Analog sensor cable distance 50–150 m depending on sensor type.
- 12V DC power — adapter included; external power is recommended for all CAN devices.
- TR (terminator) switch — enabled on the last device of the line; RUN/ERR LEDs.
- Compatible masters: VT225t, VT335G, VT336t, VT825G, VT855G, VT604G/VT608G, VT-PDU 4PS/4MS, LR800.
- Mounting: desktop, VT123 wall brackets, 19" 1U with VT125t (2 × VT408) or VT122t (VT335G + VT408), DIN rail with DRP-03.
- 129 × 28.6 × 56 mm; operating −10…+80 °C.
- Promark: sensor count and CAN line sizing, cabling plan and commissioning.
Typical applications
Data center — +8 sensors with each VT408 when the master unit's ports run out.
Remote rack group — collect sensors locally and carry them to the master over a single CAN cable.
Compact install — VT335G + VT408 together in one 1U with VT122t.
Adding analog sensors to VT-PDU and LR800, which have no analog ports.
Related Solutions
Related Products

Vutlan VT825G — 1U Data Center Monitoring Unit
19" 1U environmental monitoring and I/O control unit for mid-to-large data centers, telecom facilities and critical infrastructure. 8 analog sensor ports, CAN bus, 16 dry-contact inputs, 2 × 10A power relays and 2 × 12V outputs; scales to 130 physical sensors and 1000 elements. Gigabit LAN, dual AC/DC power options, VT7670 LTE modem and backup battery slot.
Details
Vutlan VT335G — Compact Environmental Monitoring Unit
Compact metal-housed monitoring unit for server rooms, cabinets and small-to-mid data rooms. 4 analog sensor ports, CAN bus, 4 dry-contact inputs, 2 × 12V outputs and Gigabit LAN; VT7670 LTE modem and Modbus RTU / OSDP slot. Desktop unit; mounts in 19" 1U, on DIN rail or wall with accessories.
Details
Vutlan VT125t — 19" 1U Mounting Kit for 2 × VT408
Bracket for mounting two VT408 analog sensor extension units in a standard 19" rack at 1U height, giving 16 additional analog sensor ports in a single 1U space. The older three-unit VT125 kit fits the legacy VT408 housing; VT125t is used for the current VT408 v16.1.
Details
Vutlan VT500 — Temperature Sensor
Standalone temperature sensor connecting to an analog port of Vutlan VT335G / VT825G and other master units via RJ11 6P4C cable, auto-detected. For temperature-threshold alarms, graph logging and SNMP/SMTP/SMS alerting.
Details
Vutlan VT560 — Smoke Detector
Photoelectric smoke detector connecting to the analog port of Vutlan master units. Ceiling-mounted; up to 10 detectors in a chain are monitored as one element. Delivers early smoke warnings from server rooms, cabinets and technical spaces via SNMP, e-mail or SMS.
DetailsExtension unit that adds +8 analog sensor ports to Vutlan master units over CAN bus. Sensors are auto-detected; up to 24 VT408 units can be chained on one CAN line, with bus length up to 225 m. Used when the master unit runs out of ports or sensors are clustered in a remote rack.