Vutlan Infrastructure Monitoring & Sensor System

Vutlan offers environmental monitoring and remote control for data centers, server rooms, telecom sites and industrial cabinets. VT855G / VT825G / VT335G master units, the VT604G switched PDU, the VT408 extension module and the analog/CAN sensor family provide single-point infrastructure visibility. SNMP v1/v2c/v3, web interface, logic schemes, e-mail and SMS notifications via the VT7670 LTE modem.

Family overview (15)

Master Units

Sensors

Vutlan VT490 — CAN Humidity and Temperature Sensor
Vutlan

Vutlan VT490 — CAN Humidity and Temperature Sensor

High-accuracy temperature and humidity sensor that daisy-chains over CAN bus. Connected in series on a single cable for multi-point measurement at rack fronts/backs, hot/cold aisles or around a room. Each parameter is a separate element in the web interface; dew point is calculated in the interface.

Temperature SensorHumidity SensorCAN
Details
Vutlan VT500 — Temperature Sensor
Vutlan

Vutlan VT500 — Temperature Sensor

Standalone temperature sensor connecting to an analog port of Vutlan VT335G / VT825G and other master units via RJ11 6P4C cable, auto-detected. For temperature-threshold alarms, graph logging and SNMP/SMTP/SMS alerting.

Temperature SensorAnalogRJ11
Details
Vutlan VT520 — AC Voltage Monitor
Vutlan

Vutlan VT520 — AC Voltage Monitor

Sensor that monitors AC mains — connects to Vutlan monitoring units for presence/absence detection, voltage level and outage alerts. Instant SMS/email/SNMP alarm on power cut.

AC Voltage MonitoringVT520DINPower Outage
Details
Vutlan VT530 — Door / Access Sensor
Vutlan

Vutlan VT530 — Door / Access Sensor

Magnetic access sensor that detects door open/close in server rooms, cabinets (racks), panels, vault rooms. Connects to Vutlan monitoring units via RJ11/RJ12; open events trigger SNMP trap / SMTP / SMS.

Door SensorAccess ControlMagnetic
Details
Vutlan VT560 — Smoke Detector
Vutlan

Vutlan VT560 — Smoke Detector

Photoelectric smoke detector connecting to the analog port of Vutlan master units. Ceiling-mounted; up to 10 detectors in a chain are monitored as one element. Delivers early smoke warnings from server rooms, cabinets and technical spaces via SNMP, e-mail or SMS.

Smoke DetectorSmokeAnalog
Details
Vutlan VT580 — Dust Particle / Air Quality Sensor
Vutlan

Vutlan VT580 — Dust Particle / Air Quality Sensor

Sensor that monitors dust particle concentration in data centers, clean rooms and environments with sensitive electronics. Connects to an analog port of Vutlan master units via RJ11 6P4C cable and is auto-detected; triggers SNMP trap / SMTP / SMS alerts when thresholds are exceeded.

Dust SensorAir QualityData Center
Details
Vutlan VT591 — Water Leak Sensor (with WLC Detection Cable)
Vutlan

Vutlan VT591 — Water Leak Sensor (with WLC Detection Cable)

Analog leak sensor that detects water or conductive liquid anywhere along the WLC detection cable. Provides perimeter protection under raised floors, around cooling units and at cabinet bases; alarms are sent as SNMP trap, e-mail or SMS. The WLC cable is ordered separately in 3–25 m lengths.

Water LeakLeak DetectionWLC
Details

Extensions & Accessories

Vutlan VT109 — 3-Tier Light Tower Alarm Beacon (Red/Yellow/Green)
Vutlan

Vutlan VT109 — 3-Tier Light Tower Alarm Beacon (Red/Yellow/Green)

3-tier light tower providing visual alarm notification for monitoring systems. Red (critical) / Yellow (warning) / Green (normal) three-level design. Connects directly to 12V DC, 0.25A electronic relay outputs of Vutlan monitoring units. Compatible with 3rd-party controllers. Desktop, surface, enclosure rack or wall mounting.

VutlanVT109Light Tower
Details
Vutlan VT125t — 19" 1U Mounting Kit for 2 × VT408
Vutlan

Vutlan VT125t — 19" 1U Mounting Kit for 2 × VT408

Bracket for mounting two VT408 analog sensor extension units in a standard 19" rack at 1U height, giving 16 additional analog sensor ports in a single 1U space. The older three-unit VT125 kit fits the legacy VT408 housing; VT125t is used for the current VT408 v16.1.

Mounting Kit19" Rack1U
Details
Vutlan VT408 — 8-Port Analog Sensor Extension Unit
Vutlan

Vutlan VT408 — 8-Port Analog Sensor Extension Unit

Extension unit that adds +8 analog sensor ports to Vutlan master units over CAN bus. Sensors are auto-detected; up to 24 VT408 units can be chained on one CAN line, with bus length up to 225 m. Used when the master unit runs out of ports or sensors are clustered in a remote rack.

Extension UnitCAN8 Analog Port
Details
Vutlan VT7670 — 4G LTE Slot Modem (SMS + Backup Link)
Vutlan

Vutlan VT7670 — 4G LTE Slot Modem (SMS + Backup Link)

4G LTE modem that plugs into the modem slot of Vutlan master units. Provides SMS alarm sending/receiving and Ethernet access over LTE; if the LAN link fails it switches to LTE automatically so notifications keep flowing. VT7670E for European bands, VT7670G for worldwide use.

LTE4GSMS
Details