Vertiv Liebert GXT5-5000 — Online Double Conversion UPS (5kVA / 5kW, 230V)
Online double-conversion UPS for mid-capacity critical infrastructure — 5000VA / 5000W (PF 1.0), 230V, 5U rack/tower form factor. Sinewave output, 150% overload tolerance, 7-min battery backup at 100% load (18.5 min at 50%). Scalable runtime with external battery cabinets. Gravity-sensing color LCD with auto-detection of external battery cabinets.

From the same family
Specifications
- Type
- Online double-conversion UPS
- Manufacturer
- Vertiv (Liebert series)
- Model
- GXT5-5000IRT5UXLN
- Capacity
- 5000 VA / 5000 W
- Output power factor
- 1.0
- Form factor
- Rack-tower (universal, 5U)
- Input
- 230 VAC, 50/60 Hz, hardwire
- Output
- 230 VAC sine wave, hardwire + 2 × C19 + 6 × C13
- Overload
- 150% 200ms, 125-150% 60s, 105-125% 5min
- Battery
- VRLA non-spillable lead acid
- Backup time (100% load)
- 7 minutes
- Backup time (50% load)
- 18.5 minutes
- +1 EBC at 100% load
- 19 minutes
- Dimensions
- 430 × 630 × 217 mm (W × D × H)
- Weight
- 70.8 kg
- Warranty
- 3 years full coverage (advanced replacement)
- Management
- SNMP, HTTP, IntelliSlot cards
- Certifications
- RoHS, CE, ENERGY STAR
Key features
- Online double-conversion technology — continuous power conditioning.
- Output power factor 1.0 — 5000VA = 5000W active power (1:1 ratio).
- Form factor: 5U rack-tower universal.
- Input: 230VAC, 50/60Hz (factory default 50Hz), hardwire.
- Output: 230VAC sinewave, hardwire + 2 × IEC C19 + 6 × IEC C13.
- Overload: 150% min 200ms, 125–150% for 60s, 105–125% 5min, ≤105% continuous.
- Battery: valve-regulated non-spillable lead acid (VRLA).
- Backup time: 7 min at 100% load; 18.5 min at 50%.
- External battery cabinet (+1) for 19 min at 100% load.
- Gravity-sensing color LCD — orientation-aware UI.
- Auto-detection of external battery cabinets.
- Dimensions: 430 × 630 × 217 mm (W × D × H); weight 70.8 kg.
- 3-year full-coverage factory warranty (advanced replacement); extended option available.
- Promark: load-profile sizing, external battery cabinet planning, rack integration, network management (SNMP/HTTP) configuration.
Typical applications
Data-center mid-rack — critical server backup with scalable runtime.
Telecom edge — operator core router + IP DECT base station backup.
Hospital HIS — server-room continuous operation.
Industrial control room — PLC + HMI + DCS server backup.
Government building critical load — PBX + IP phones + security cameras.
Related Solutions
Related Products

Vertiv Liebert GXT RT+ — Online Double Conversion UPS (1-3 kVA)
Affordable online double-conversion UPS for edge network equipment and space-constrained facilities — rack or tower form factor, 0.9 high power factor, ECO mode at 95%+ efficiency, scalable runtime via external battery cabinet. 4 models: 1000 / 1500 / 2000 / 3000 VA.
Details
Exide GNB Sprinter P12V875 — 12V 41Ah VRLA AGM Battery
High-rate emergency backup battery for UPS and security systems — Exide GNB Sprinter P/XP series (NAPW120875HP0MC). 1157W per block at 10-minute 1.6V/C discharge @ 25°C, 41Ah at 10-hour 1.8V/C. EUROBAT 'Long Life' 10-12 year design life, maintenance-free AGM technology.
Details
Exide GNB Sprinter XP12V1800 — VRLA/AGM Battery (12V 56.4Ah)
High-wattage maintenance-free VRLA/AGM battery — for UPS, telecom DC power and emergency lighting. 1840 W/block over a 10-minute discharge (1.60 V/cell, 25 °C); EUROBAT 2015 'Long Life 10–12 years' classification; standard or UL 94-V0 flame-retardant version; designed in accordance with IEC 60896-21/-22.
Details
Eltek Flatpack2 HE — 48V Telecom DC Power Rectifier System
High-efficiency (96% at nominal input) Flatpack2 HE 48V rectifier system for telecom and data center DC power infrastructure. 2000W and 3000W module options scaling from 8kW 2U racks with complete distribution to multi-cabinet, multi-MW installations. MTBF >350,000 h (2000W) / >300,000 h (3000W) at 25 °C.
DetailsOnline double-conversion UPS for mid-capacity critical infrastructure — 5000VA / 5000W (PF 1.0), 230V, 5U rack/tower form factor. Sinewave output, 150% overload tolerance, 7-min battery backup at 100% load (18.5 min at 50%). Scalable runtime with external battery cabinets. Gravity-sensing color LCD with auto-detection of external battery cabinets.