Eltek Flatpack2 Integrated 48V (2U 150A · 5U-7U 300/500A · 5U-8U 600/700A)

Eltek Flatpack2 Integrated — Complete 48 V DC Power Systems (150–700 A)

Complete -48 VDC power systems configured with Flatpack2 rectifiers, controller, battery and load distribution. 2U Integrated up to 150 A, 5U–7U Integrated 300 A / 500 A, 5U–8U Integrated 600 A and 700 A (36 kW). Smartpack R, Smartpack2 or Smartpack S controller; hot-plug HE/SHE rectifiers, LVBD, plug-in battery breakers and DIN-rail load MCBs. For PBX rooms, base stations, transmission and the data center DC power layer.

DC PowerPower System-48V150A300A500A600A700ASmartpack RSmartpack2LVBDHot Pluggable19" Rack
Eltek Flatpack2 Integrated — Complete 48 V DC Power Systems (150–700 A)

From the same family

Specifications

Type
Complete -48 VDC power system: rectifiers + controller + battery and load distribution
Manufacturer
Eltek (Delta Group)
Models
2U Integrated 150 A · 5U–7U Integrated 300 A / 500 A · 5U–8U Integrated 600 A / 700 A
Rectifier
Flatpack2 48/2000 and 48/3000, HE or SHE (5U–8U 24 V: 24/1800 HE)
Max output current
150 A (2U) · 300 / 500 A (5U–7U) · 600 / 700 A (5U–8U)
AC input
85–300 VAC (HE) / 85–264 VAC (SHE), 45–66 Hz
Battery distribution
2U: 2 × max 100 A · 5U–7U: 4/6 × 100 A (300 A), 8 × 100 A (500 A) · 5U–8U: 6 × 100 A (600 A), 8 × 100 A (700 A)
Load distribution
2U: 6 MCBs (2–32 A or 2–60 A) · 5U–7U: up to 20 / 16 × 18 mm positions · 5U–8U: up to 18 × 18 mm positions; DIN-rail MCBs
Controller
Smartpack R (2U, 5U–8U) · Smartpack2 or Smartpack S (5U–7U 300 A) · Smartpack2 (5U–7U 500 A)
Smartpack R I/O
6 digital inputs, 6 alarm relays; Ethernet, USB-A, USB-B
Dimensions (W × D × H)
482 × 370 × 89 mm (2U) · 482 × 380 mm, H: 222 mm (5U) – 356 mm (8U)
Operating temperature
-40…+65 °C (2U) · -40…+70 °C (5U–7U) · -40…+60 °C (5U–8U)
Standards (2U)
EN IEC 62368-1; ETSI EN 300 386; EN 61000-6-2/-3; ETSI EN 300 019-2-1/2/3; ETSI EN 300 132-2

Key features

  • 2U Integrated: 19" 2U, max 150 A at -48 VDC; Smartpack R controller; 2 battery breakers (max 100 A), optional 150 A LVBD; 6 load MCBs (32 A or 60 A distribution), optional PLD
  • 2U Integrated input: 85–300 VAC (HE) / 85–264 VAC (SHE), 45–66 Hz; 1-phase 230 VAC or 3-phase 400 VAC TN, 1-phase or 3-phase 230 VAC IT mains, or individual input per module
  • 5U–7U Integrated: 300 A (4 or 6 × 100 A battery breakers, up to 20 × 18 mm load positions) and 500 A (8 × 100 A battery breakers, up to 16 load positions); 4U distribution chassis; LVBD as standard
  • 5U–7U controller: Smartpack2 or Smartpack S (300 A), Smartpack2 (500 A); door-panel mounted, menu-guided operation via colour display and keypad, web monitoring over Ethernet
  • 5U–8U Integrated: -48 VDC 600 A (48/2000 or 48/3000 HE/SHE) and 700 A / 36 kW (48/3000); 6 or 8 × 100 A battery breakers; up to 18 load MCB positions; Smartpack R; 24 VDC 600 A option (24/1800 HE)
  • Smartpack R: 6 digital inputs for monitoring external equipment, 6 alarm relays; Ethernet port, USB-A (e.g. Wi-Fi adapter, flash drive) and USB-B
  • Hot-plug Flatpack2 HE and SHE rectifiers; unused slots are closed with blind panels and modules are added while the system runs as the load grows
  • System operating temperature: 2U -40…+65 °C, 5U–7U -40…+70 °C, 5U–8U -40…+60 °C

Typical applications

01

PBX room: -48 V DC supply for OpenScape 4000 and transmission equipment, together with the battery bank in one system

02

Base station and microwave site (2U Integrated, 150 A)

03

Fiber / FTTx and broadband node

04

High-current -48 V DC layer in central offices and data centers (5U–8U Integrated, 600–700 A)

Related Solutions

Related Products

Eltek Flatpack2 — Telecom DC Rectifier Family (24/48/60 V, HE & SHE)

Eltek Flatpack2 — Telecom DC Rectifier Family (24/48/60 V, HE & SHE)

High-efficiency (96% at nominal input) Flatpack2 HE 48V rectifier system for telecom and data center DC power infrastructure. 2000W and 3000W module options scaling from 8kW 2U racks with complete distribution to multi-cabinet, multi-MW installations. MTBF >350,000 h (2000W) / >300,000 h (3000W) at 25 °C. The family also includes 24/1800 HE, 48/2000 and 48/3000 SHE (up to 97.8% efficiency), 48-60/2000 HE and 60/3000 SHE modules; the 110 and 220 V models are on the Industrial DC page.

Details
Eltek Flatpack S — 1U Compact 48V DC Power System

Eltek Flatpack S — 1U Compact 48V DC Power System

Compact 48V DC power system in 262 mm depth, 1U high — fits in small infrastructure cabinets, used in small switches and branches. Smartpack S controller + 2-3 rectifiers (1000W or 1800W modules) + battery + load distribution in one 1U platform. Remote management over Ethernet.

Details
Exide GNB Sprinter XP12V1800 — VRLA/AGM Battery (12V 56.4Ah)

Exide GNB Sprinter XP12V1800 — VRLA/AGM Battery (12V 56.4Ah)

High-wattage maintenance-free VRLA/AGM battery — for UPS, telecom DC power and emergency lighting. 1840 W/block over a 10-minute discharge (1.60 V/cell, 25 °C); EUROBAT 2015 'Long Life 10–12 years' classification; standard or UL 94-V0 flame-retardant version; designed in accordance with IEC 60896-21/-22.

Details
OpenScape 4000 EcoServer 2 — Mission-Critical Communications Platform

OpenScape 4000 EcoServer 2 — Mission-Critical Communications Platform

Enterprise-grade PBX server for government, hospital, airport and large-campus deployments — Linux-based (SLES), 12,000 subscribers per single system, up to 100,000 when networked, with geo-redundant Hot-Standby Duplex.

Details
Eltek Flatpack2 Integrated — Complete 48 V DC Power Systems (150–700 A)

Complete -48 VDC power systems configured with Flatpack2 rectifiers, controller, battery and load distribution. 2U Integrated up to 150 A, 5U–7U Integrated 300 A / 500 A, 5U–8U Integrated 600 A and 700 A (36 kW). Smartpack R, Smartpack2 or Smartpack S controller; hot-plug HE/SHE rectifiers, LVBD, plug-in battery breakers and DIN-rail load MCBs. For PBX rooms, base stations, transmission and the data center DC power layer.