Promark
WhatsApp
All products
OpenScape 4000 SIUX3 (Signaling Interface Unit eXtended)

OpenScape 4000 SIUX3 — DTMF/MFC Signaling Interface Card

Peripheral signaling card on the OpenScape 4000 platform — supports 8-channel DTMF / MFC sender/receiver pairs, line diagnostics (TDS) and country-specific signaling. Successor to the SIUX/SIUX2 family.

OS4000SignalingDTMFMFCTDSDiagnostic8 Channel
OpenScape 4000 SIUX3 — DTMF/MFC Signaling Interface Card

Specifications

Tip / Type
Signaling Interface Unit eXtended (peripheral)
Kanal sayısı / Channels
8
Operasyon modları / Function IDs
6 (FID 2–7)
Konnektör / Connector
SIPAC (SIVAPAC legacy değildir)
Central SIU olarak / Use as central SIU
Hayır
Loadware varyantları / LW variants
DTMF, MFC, DTMF+TDS, MFC ANI, MFC shuttle, DTMF+Line check
Hat tanılama / Line diagnostics
TDS (Function ID 4) veya Line check (Function ID 7)
Hot-plug
Evet
OpenScape 4000 sürümü / OS4K version
V11

Key features

  • 8-channel capacity — receives and transmits signals to/from trunks and subscriber equipment.
  • Six operating modes (Function ID 2–7), each with its own loadware:
  • · Function ID 2: 8 DTMF sender/receiver pairs (DTMF countries).
  • · Function ID 3: 8 MFC sender/receiver pairs (MFC countries).
  • · Function ID 4: 4 DTMF pairs + 1 TDS (Telephony Diagnostic System) port.
  • · Function ID 5: MFC ANI (Russia/CIS).
  • · Function ID 6: MFC shuttle-packet (Russia/CIS).
  • · Function ID 7: 4 DTMF pairs + 1 Line check diagnostics.
  • SIPAC connector (cannot be used as a central SIU; older SIVAPAC variant is the legacy form).
  • Hot-pluggable: removal/replacement in §6.3.2/6.3.3.
  • Compatible with HiPath 4000 V8+ on the OpenScape 4000 V11 platform.

Typical applications

01

European enterprise PBX — DTMF Function ID 2 (8 pairs) for operator menus and IVR.

02

Latin America or North Africa — MFC Function ID 3 signaling.

03

Russian / CIS market — MFC ANI (Function ID 5) for caller ID.

04

Service and maintenance — automated line diagnostics via TDS Function ID 4.

05

Multi-country organizations — same card, country-specific loadware.

Related Solutions

Related Products

OpenScape 4000 SIUX3 — DTMF/MFC Signaling Interface Card

Peripheral signaling card on the OpenScape 4000 platform — supports 8-channel DTMF / MFC sender/receiver pairs, line diagnostics (TDS) and country-specific signaling. Successor to the SIUX/SIUX2 family.