# OScAR alarm and notification server

An alarm server that informs the right people, in the right order, by phone and message when an emergency call, fault or fire alarm comes in. As a Mitel Silver Partner, Promark delivers OpenScape Alarm Response (OScAR) from scenario design to commissioning.

Source: https://www.promark.tr/en/solutions/platforms/openscape-alarm-response

**Mitel Silver Partner** — Promark

## What does it do?

OpenScape Alarm Response (OScAR) is an alarm and communication server that distributes alarms and information reliably. The trigger can be a phone call, a nurse call system, a fire panel, a contact input, an e-mail or an SNMP message. OScAR calls people and groups in parallel or in sequence by voice message, text message, e-mail or SMS, waits for acknowledgement, moves to the next person if there is no answer and, if needed, joins the people involved in an automatic conference.

The server connects to the PBX through a coded trunk with direct dial-in (DDI) and appears to the PBX as a subsystem with its own numbering plan. The connection uses SIP-Q, SIP or CorNet-NQ; it works with OpenScape 4000, OpenScape Business, OpenScape Voice and HiPath 3000. On OpenScape 4000 an alarm call can intrude on a busy line and override call forwarding and do-not-disturb.

There are two product lines: OScAR-Pro for large and complex scenarios, which can be installed as a redundant cluster, and OScAR-Eco, a browser-managed server for standard alarm tasks at small to mid-size scale. Both are Mitel OEM products based on tetronik DAKS.

## Which scenarios?

- **Hospitals: nurse call and emergency team:** A patient call reaches the nurse's DECT or WLAN phone as a message, with call-back to the room. When the emergency number is dialled, doctor, security and technical staff are joined automatically in a conference.
- **Lone workers:** Deliberate alarm with the emergency button; automatic alarm with man-down and no-movement (M3 Plus, M3 Ex Plus, WL4 Plus). The alarm is sent with the location derived from the base station.
- **Mass notification and crisis communication:** Voice and text messages to hundreds of people at once during an evacuation, hazard or crisis. Acknowledgements are tracked.
- **Escalation and on-call chains:** On a fault or alarm, the call list is worked through until the required number of people have acknowledged. On-Call Management decides who is called according to the duty roster.
- **Building services, energy and production:** Fault messages from the fire panel, building automation, SCADA or contact inputs reach the technical team by phone and text; ESPA 4.4.4 and ESPA-X interfaces.

## Key features

- Parallel and sequential calling, acknowledgement (accept / reject) and escalation to the next target when there is no acknowledgement
- Mass notification: up to 2,000 groups, 8,000 subscribers per group, 20 simultaneous broadcasts (expandable to 40)
- Emergency conference: automatic conference with the alarm initiator and the called people; up to 60 participants per conference on OScAR-Pro
- Personal security: emergency button, man-down and no-movement alarms; location by DECT base station and signal strength
- On-Call Management, Info Telephone and custom operator interfaces (DCO Designer)
- Triggers: phone, ESPA 4.4.4 / TAP serial port, ESPA-X (LAN), contact inputs, e-mail (Mail2Phone), SNMP
- Message output: text and voice messages to DECT and WLAN phones, SMS, e-mail; OScAR Mobile (iOS / Android) and Desktop clients
- OScAR-Pro redundancy: cluster of 2 active (load-sharing) + 2 hot-standby servers; dual power supply; no rotating parts (no hard disks, no fans)
- OScAR-Pro 400: Secure Boot, signed operating system and AES256 SSD encryption; encrypted VoIP (SRTP / TLS)
- Microsoft Teams integration

## OScAR-Pro and OScAR-Eco compared

|  | OScAR-Pro 200 | OScAR-Pro 300 | OScAR-Pro 400 | OScAR-Eco 100 | OScAR-Eco 200 |
|---|---|---|---|---|---|
| Target scale | Large and complex scenarios | Large; sites that need ISDN | Large; VoIP only | Small scale, standard alarm tasks | Small to mid-size, standard alarm tasks |
| Hardware | 19" 1U | 19" 3U, rack or desktop | 19" 2U, fanless | Desktop, PoE | 19" 1U |
| Parallel channels | 5–30 | 5–480 (480 with ISDN; encrypted VoIP 60) | 5–500 | 5–10 | 5–30 |
| PBX connection | SIP / SIP-Q, encrypted | SIP / SIP-Q; ISDN S0/S2M (QSIG, CorNet-NQ, DSS1) | SIP / SIP-Q, encrypted | QSIG, CorNet-NQ, SIP, SIP-Q (VoIP) | QSIG, CorNet-NQ, SIP, SIP-Q (VoIP) |
| ESPA 4.4.4 serial ports | 2 | Up to 8 | 4 | 2 | 2 |
| ESPA-X | 5 | Up to 60 | Up to 60 | 1 | Up to 5 |
| Capacity | 20,000 subscribers · 2,000 call profiles · 100 user groups | 20,000 subscribers · 2,000 call profiles · 100 user groups | 20,000 subscribers · 2,000 call profiles · 100 user groups | 1,000 call groups (100 in the base package) · 25 targets per call | 1,000 call groups (100 in the base package) · 25 targets per call |
| Conference | 1,000 conferences, 60 participants, 20 simultaneous | 1,000 conferences, 60 participants, 20 simultaneous | 1,000 conferences, 60 participants, 20 simultaneous | 10 conferences (emergency, panic, Meet-Me) | 10 conferences (emergency, panic, Meet-Me) |
| Redundancy | Cluster: 2 active + 2 hot-standby | Cluster: 2 active + 2 hot-standby | Cluster: 2 active + 2 hot-standby | — | — |

Source: tetronik DAKSpro V9.1x and DAKSeco V3.10 Data Sheet and Product Info; Mitel OScAR V5 service documentation. Where sources give different values, the Data Sheet value is shown. The exact channel and module configuration is fixed in the BOM together with the scenario design.

## OScAR-Pro or OScAR-Eco?

**OScAR-Pro**

- 20,000 subscribers, up to 500 parallel channels
- Redundant cluster: 2 active + 2 hot-standby servers
- Modules such as personal security, on-call management, positioning and custom operator interfaces
- Large and complex scenarios such as hospital campuses, energy sites and public crisis centers

**OScAR-Eco**

- 100: 5–10, 200: 5–30 parallel channels
- Compact, browser-managed device
- Standard tasks such as nurse call, silent fire panel alarm, production faults and building services messages
- Small and mid-size organizations

## What Promark delivers

- Scenario analysis: who is informed about which event, in which order and over which channel
- Datasheet-based design; BOM and license list within 24–48 hours
- PBX connection (SIP-Q / CorNet-NQ / ISDN) and numbering plan
- Integration with nurse call, fire panels and building automation (ESPA, contact inputs)
- Commissioning of alarms, man-down and messaging on DECT and WLAN phones
- Test scenarios and user training
- Annual maintenance; field service across Türkiye and in Turkmenistan

## Sectors

- [Hospitals](https://www.promark.tr/en/solutions/healthcare)
- [Energy & Industry](https://www.promark.tr/en/solutions/energy)
- [Public & Critical Facilities](https://www.promark.tr/en/solutions/public)

## Related use cases

- [Critical communications & incident/alarm management](https://www.promark.tr/en/solutions/critical-communications)

## Related catalog products

- [OpenScape Alarm Response Pro V5 (OScAR-Pro)](https://www.promark.tr/en/products/oscar)
- [Mitel OpenScape Alarm Response Eco V5 (OScAR-Eco)](https://www.promark.tr/en/products/oscar-eco)
- [OpenStage M3 Family — Industrial and ATEX DECT Handset](https://www.promark.tr/en/products/m3)
- [OpenScape WLAN Phone WL4 Plus — Wi-Fi SIP Handset with Alarms](https://www.promark.tr/en/products/wl4-plus)
- [WSG Server — WL4 Wireless Service Gateway](https://www.promark.tr/en/products/wsg-server)
- [OpenScape Cordless IP V2 — Enterprise IP-DECT Mobility System](https://www.promark.tr/en/products/cordless-ip-v2)
- [OpenScape DECT Phone SL7 — Flagship Slim DECT Handset](https://www.promark.tr/en/products/sl7)
- [All products in the family](https://www.promark.tr/en/products/oscar-alarm-response)

## Frequently asked questions

### What is an alarm server?

An alarm server informs predefined people and groups by phone, text message, e-mail or SMS when an event occurs (emergency call, fire alarm, fault, patient call). It tracks who has acknowledged, calls the next person if there is no answer and, if needed, joins the people involved in a conference. OScAR is an alarm server that works connected to the PBX.

### What is the difference between OScAR-Pro and OScAR-Eco?

OScAR-Pro is for large and complex scenarios: 20,000 subscribers, up to 500 parallel channels, redundant cluster and modules such as personal security and on-call management. OScAR-Eco is a compact, browser-managed device for standard alarm tasks; the 100 model offers 5–10 and the 200 model 5–30 parallel channels.

### How is a nurse call system connected to the phones?

The nurse call system connects to OScAR via an ESPA 4.4.4 serial port, ESPA-X (LAN) or a contact input. OScAR forwards the call as a text message to the responsible nurse's DECT or WLAN phone; the nurse acknowledges the message and can call back to the room. If there is no answer, the call is routed to the next person.

### How does a lone worker alarm work?

Staff carry an M3 Plus, M3 Ex Plus or WL4 Plus phone. Pressing the emergency button starts the alarm deliberately; man-down or no-movement detection starts it automatically. OScAR sends the alarm to the team with the location derived from the base station and signal strength, and keeps escalating until it is acknowledged.

### How many people can a mass notification reach at once?

The OScAR-Pro broadcasting module supports up to 2,000 groups with up to 8,000 subscribers each. 20 broadcasts run simultaneously, expandable to 40. How many people are reached at the same moment depends on the number of parallel channels installed; OScAR-Pro 400 goes up to 500 channels.

### Which PBXs does OScAR work with?

OScAR works with OpenScape 4000, OpenScape Business, OpenScape Voice and HiPath 3000 over SIP-Q. On OpenScape 4000, with a CorNet-NQ connection, an alarm call can intrude on a busy line, override call forwarding and do-not-disturb and send multi-line messages to the display of HFA phones.

## Alarm server quote

Send us the PBX type, the alarm scenarios (nurse call, lone worker, fire, fault, mass notification), the number of people and groups and the phones to be used by WhatsApp. We return a BOM and quote within 24–48 hours. Across Türkiye and in Turkmenistan.

- Request a quote: https://www.promark.tr/en/contact
- WhatsApp: https://wa.me/903125440915?text=Hello%2C%20I%20would%20like%20a%20quote%20for%20the%20OScAR%20alarm%20server.
- Call: +90 312 544 0915
- E-mail: destek@promark.tr
- Promark Dijital Teknolojiler Limited Şirketi — İvedikköy Mah. İvedik Cad. No: 245/38 06378 Yenimahalle / Ankara